The extraction force shall be within the range of 6 n to 20 n after 10,000 insertionextraction cycles. D same as g except, these connectors are intended for space. Contact resistance voltage drop eia 364 06 using test currents as defined. Durability eia 364 09 10,000 cycles no evidence of physical damage durability preconditioning eia 364 09 50 cycles no evidence of physical damage reseating manually unlugplug the connector. Pdf acrobat reader or word version doc document file size.
Apply gold to the inside and outside diameter of the contact in area x or y. Eia36420 no flashover, sparkover, or breakdown 900 vac pass insulation resistance eia36421 m. Connectors, electric, rectangular, nonenvironmental, miniature, polarized shell, rack and panel, general specifcation for, eia 364 20 datasheet, eia 364 20 circuit. Item test condition requirement status durability eia36409c cycles 30 au pass random vibration. Amp test specifications vs eia and iec test methods. Environmental performance of electrical connectors. Measure gold thickness in zone a or b, as applicable. Eca eia36420d2008 tp20d withstanding voltage test procedure for electrical connectors, sockets, and coaxial contacts publisher. The force shall be applied 6 inches from the mating face of the connector to the cable and shall pullaway from the. Test between adjacent contacts of unmated connector assemblies. If a sample fails to pass group b inspection, the manufacturer shall notify the qualifyingactivity and the cognizant inspection activity of such failure and take corrective action on the materials or processes, orboth, as warranted, and on all units of product which can be corrected and which were manufactured using essentiallythe same.
Measure goldthickness on outside diameter of the contact at point b or c, as applicable. Eia 364 9 datasheet, cross reference, circuit and application notes in pdf format. Eia 36420b tp20b withstanding voltage test procedure for electrical connectors, sockets, and coaxial contacts. Cross reference of eia 364 procedures and mil std 44 methods. Withstanding voltage test procedure for electrical connectors, sockets and. Energy information administration, a look at commercial buildings in 1995.
Eia 364 20c datasheet, cross reference, circuit and application notes in pdf format. Eia 364 20 and milstd44 both dictate that the dielectric withstanding voltage dwv be established as 75% of the minimum breakdown voltage of the connector breakdown voltage is defined as the voltage at which a connector failure is observed. An axial force of 8 ounces per contactshall be applied. Contact resistance eia 364 23 8 milliohms at 3 amps. This standard also includes administrative details and guidelines for connectorsocket qualification and an annex for pertinent technical information. Apply 300v ac for 1minute between adjacent terminal or ground. Characteristics, energy consumption, and energy expenditures. This standard establishes a test method to impose axial forces on the connector contacts to determine the ability of the connector to withstand forces that tend to displace contacts from their proper location within the connector insert and resist contact pullout. The unmated wired connector with strain relief, when applicable,shall be mounted by normal mounting means and aligned with the test fixture. Insulation may degrade if the connector is exposed to repeated dwv tests and the dwv test voltage. Eia36410 datasheet, cross reference, circuit and application notes in pdf format. Eia eca 364 mating and unmating forces test procedure for electrical connectors and sockets. Solderability of contact terminations test procedure for electrical connectors eia36452 revision b superseded see the following.
Eca eia36441d2008 tp41d cable flexing test procedure for electrical. Amsc nafsc 5935mildtl24308gwamendment 21 august 2012supersedingmildtl24308gwamendment 125 january 2011detail specification datasheet search, datasheets, datasheet search site for electronic components and semiconductors, integrated circuits, diodes and other semiconductors. Connectors, electric, rectangular, nonenvironmental, miniature, polarized shell, rack and panel, general specifcation for, eia 364 datasheet, eia 364 circuit. No flashover, no sparkover, no excess leakage, no breakdown.
Eia 364 21 insulation resistance test procedure for electrical connectors, sockets, and coaxial contacts eia 364 23 low level contact resistance test. Connectors, electric, rectangular, nonenvironmental, miniature, polarized shell, rack and panel, general specifcation for, eia 364 29 datasheet, eia 364 29 circuit. Eia 364 20 withstanding voltage test procedure for electrical connectors, sockets and coaxial. On socket contacts with integral pressure members, area x zone of tangency extends from the tip of. This method is to evaluate the dielectric withstanding voltage of electrical connectors, sockets and coaxial contacts. The resistance of an equal length of wire reference wire shall be subtracted from the same reel as used for the connector wiring. Eia36420 datasheet, cross reference, circuit and application notes in pdf format.
Eia 364 08 crimp tensile strength test procedure for electrical connectors eia 364 20 withstanding voltage test procedure for electrical connectors, sockets and coaxial contacts. Connectors shall show no evidence of breakdown or flashover when subjected to the dwv test of eia 364 procedure 20. Eia 364 09 connectors and contacts, electrical, durability test procedure for eia 364 10 fluid immersion test procedure for electrical connectors eia eca 364 mating and unmating forces test procedure for electrical connectors and sockets eia 364 20 connectors, sockets and coaxial contacts, electrical, withstanding voltage test. Tp20f dielectric withstanding voltage test procedure for electrical connectors, sockets and coaxial contacts. Eia36420 pdf, eia36420 description, eia36420 datasheets. Connectors, electric, rectangular, nonenvironmental, miniature, polarized shell, rack and panel, general specifcation for, eia36420 datasheet, eia 364 20 circuit. Eia36420 datasheet, eia36420 datasheets, eia36420 pdf, eia36420 circuit. Itt connectors, electric, rectangular, nonenvironmental, miniature, polarized shell, rack and panel, general specifcation for,alldatasheet, datasheet, datasheet search site for electronic components and semiconductors, integrated circuits, diodes, triacs, and other semiconductors. Unmated connectors shall be tested in accordance with test procedure eia 364 20, condition i. Tp20f dielectric withstanding voltage test procedure. Eia provides a forum for industry to develop standards and publications for the electronic components industry. Eia 364 20b tp20b withstanding voltage test procedure for electrical connectors, sockets, and coaxial contacts. Test with applied voltage not to exceed 20 mv open circuit and the test current shall be limited to 100 ma.
For windows 10 users to view download pdf documents, the adobe reader dc version. Eia 364 8 datasheet, cross reference, circuit and application notes in pdf format. Eia 364 20 datasheet, cross reference, circuit and application notes in pdf format. Itt detail specification,alldatasheet, datasheet, datasheet search site for electronic components and semiconductors, integrated circuits, diodes, triacs, and other semiconductors. Electronic industries alliance the electronic industries alliance eia is an ansiaccredited standards development organization managed by the electronic components association eca standards and technology department. Electronic products and services users can view and download selected pages, sections, or entire reports, search for information, download data and analysis applications, and find out about new information. May 2, 2008 eia standard tp38ceia 364 38c cable pullout test procedure for electrical connectors eia 364 38c revision of eia 364 38b may 2008 eia standards electronic components association. Eia364 10 datasheet, cross reference, circuit and application notes in pdf format. Electronic components, assemblies and materials association eca file format. Connectors shall meet dwv, contact resistance, shelltoshell resistance. This standard establishes a recommended minimum test sequence and test procedures for electrical connectors and sockets.
Eia364 52 datasheet, cross reference, circuit and application notes in pdf format. Connectors covered by this specification are of the following classes. Eia36420c datasheet, cross reference, circuit and application notes in pdf format. M same as n except, these connectors are intended for space missions. This method is to evaluate the insulation resistance of electrical connectors, sockets and coaxial contacts. Test between adjacent contacts and contacts to shell.
1204 230 1613 1582 851 325 1598 1503 421 961 274 563 631 81 723 39 586 320 1528 655 14 1073 602 732 13 1338 955 557 466 110 1353 1059 1305 487